Posiflex HS-2510W-TS Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Posiflex HS-2510W-TS. Posiflex HS-2510W-TS User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
FCC Notes: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions manual,
may cause interference to radio communications. It has been tested and found to comply with limits for a Class A digital device pursuant to EN55022 and 47
CFR, Part 2 and subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to
take whatever measures to correct the interference.
For CE-countries: This scanner is in conformity with CE standards. Please note that an approved, CE-marked power supply unit should be used in order to
maintain CE conformance.
Laser Safety: The laser scanner complies with safety standard IEC 60825 –1 for a Class I laser produce. It also complies with CDRH as applicable to a
Class IIa laser product. Avoid long term staring into direct laser light.
Radiant Energy: The laser scanner uses one low-power visible laser diodes operating at 650nm in an opto-mechanical scanner resulting in less than 3.9μW
radiated power as observed through a 7mm aperture and averaged over 10 seconds.
Do not attempt to remove the protective housing of the scanner, as unscanned laser light with a peak output up to 0.8mW would be accessible inside.
Laser Light Viewing: The scan window is the only aperture through which laser light may be observed from this product. A failure of the scanner motor,
while the laser diode continues to emit a laser beam, may cause emission levels to exceed those for safe operation. The scanner has safeguards to prevent this
occurrence. If, however, a stationary laser beam is emitted, the failing scanner should be disconnected from its power source immediately.
Adjustments: Do not attempt any adjustments or alteration of this product. Do not remove the protective housing of the scanner. There are no user-
serviceable parts inside.
Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.
Optical: The use of optical instruments with this product will increase the eye hazard. Optical instruments include binoculars, magnifying glasses, and
microscopes but do not include normal eye glasses worn by the user.
Warranty Limits: Warranty terminates automatically when any person other than the authorized technicians opens the machine. The user should consult
his/her dealer for the problem happened. Warranty voids if the user does not follow the instructions in application of this merchandise. The manufacturer is
by no means responsible for any damage or hazard caused by improper application.
No part of this document may be reproduced, transmitted, stored in a retrieval system, transcribed, or translated into any language or computer language in
any form or by any means electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without express written consent and authorization.
We reserve the right to make changes in product design without reservation and without notification. The material in this guide is for information only and
is subject to change without notice.
All trademarks mentioned herein, registered or otherwise, are the properties of their various respective owners.
About This Manual:
Posiflex Technologies, Inc. has made every effort for the accuracy of the content in this manual. However, Posiflex Technologies, Inc. will assume no
liability for any technical inaccuracies or editorial or other errors or omissions contained herein, nor for direct, indirect, incidental, consequential or
otherwise damages, including without limitation loss of data or profits, resulting from furnishing, performance, or use of this material.
This information is provided “as is” and Posiflex Technologies, Inc. expressly disclaims any warranties, expressed, implied or statutory, including without
limitation implied warranties of merchantability or fitness for particular purpose, good title and against infringement.
The information in this manual contains only essential hardware concerns for general user and is subject to change without notice. Posiflex Technologies,
Inc. reserves the right to alter product designs, layouts or drivers without notification. The system integrator shall provide applicative notices and
arrangement for special options utilizing this product. The user may find the most up to date information of the hardware from:
http://www.posiflex.com
or
http://www.posiflex.com.tw
or http://www.posiflexusa.com
All data should be backed-up prior to the installation of any drive unit or storage peripheral. Posiflex Technologies, Inc. will not be responsible for any loss
of data resulting from the use, disuse or misuse of this or any other Posiflex product.
All rights are strictly reserved. No part of this documentation may be reproduced, stored in a retrieval system, or transmitted in any form or by any means,
electronic, mechanical, photocopying, or otherwise, without prior express written consent from Posiflex Technologies, Inc. the publisher of this
documentation.
© Copyright Posiflex Technologies, Inc. 2014
All brand and product names and trademarks are the property of their respective holders.
HS-251xW-TS Series
15590904010 Ver. Original
Laser Bar
code Scanner
User’s Manual
http://www.posiflex.com
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - User’s Manual

1 FCC Notes: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instru

Page 2

Message Terminator-Enter Message Terminator-H.tab Message Terminator-None Return to Customer Default N

Page 3 - SCANNER SETUP (PROGRAMMING)

Save as Customer Default Codabar Enable Codabar Disable Code 39 Enable 11

Page 4

Code 39 Disable Full ASCII Code 39 Enable Full ASCII Code 39 Disable UPC/EAN/JAN Enable 12

Page 5 - OPERATING THE SCANNER

UPC/EAN/JAN Disable ITF 2 of 5 Enable ITF 2 OF 5 Disable UPC/EAN Add ON OFF 13

Page 6 - SCANNER MAINTANTENCE

Add ON 5 only Add ON 2 only Add ON 2 or 5 EAN/UPC +Add ON (none mandatory) 14

Page 7 - TROUBLE SHOOTING GUIDE

EAN/UPC + Add ON (mandatory) Force UPC-A to EAN-13 Format Enable Force UPC-A to EAN-13 Format Disable EAN-13 Convert to ISBN/I

Page 8 - PROGRAMMING CODES

EAN-13 Convert to ISBN/ISSN Disable EAN-128 Enable EAN-128 Disable Code 128 Enable 16

Page 9

Code 128 Disable Code 93 Enable Code 93 Disable Chinese Post Code Enable 17

Page 10

Chinese Post Code Disable Code 32 (Italian Pharmacy Code) Enable Code 32 (Italian Pharmacy Code) DisableMSI Enable 18

Page 11

MSI Disable Enter/Exit Programming Mode 19

Page 12

Using the Scanner Introduction to the Laser Barcode Scanner Features The scanner unit is a compact omni-directional laser scanner. Featured with Z-sca

Page 13

20 < MEMO >

Page 14

3 Operation Status When the scanner powers up, the buzzer gives four beeps. Present a known-good test barcode to the scanner. The scanner should issue

Page 15

4 Scan Test Power on the scanner of the host system and open the text editor on the host system. Then, try to scan several valid barcodes. Check the r

Page 16

5 Read the <Enter/Exit programming mode> barcode to start configuration Change scanner setting by scanning a required mode barcode Displ

Page 17

Omni-Directional Scan Mode The scanner will always stay active in the Omni-directional Scan mode in normal operation. In other words, the scanner will

Page 18

7 Cleaning the Scan Window Wipe the scan window with a soft lint-free cloth and a non-abrasive cleaner to avoid the scan window from being scratched a

Page 19

8 Problem Diagnostic Tips The communication settings of the system port and the scanner do not match. Adjust the settings to make them match to each

Page 20 - < MEMO >

Abort Note: The reading of the “Abort” barcode discards all the parameters changed previously. However the reading of the “Enter/Exit of Prog

Modèles reliés HS-2512W | JIVA HS-2510W |

Commentaires sur ces manuels

Pas de commentaire